Abstract
蒋先敏,孔健,林涛,于秀英,陈颖,戴雨,杨航燕,孙晓丽,杨剑,杨永泉,张艳春.甲胎蛋白胶体金诊断试剂临床应用研究[J].Chinese journal of Epidemiology,2003,24(3):210-212
甲胎蛋白胶体金诊断试剂临床应用研究
Study on the clinical use of alpha-fetoprotein (AFP) colloidal gold diagnostic strip
Received:June 20, 2002  
DOI:
KeyWord: 胶体金试验  甲胎蛋白  临床研究
English Key Word: Colloidal gold test  Alpha-fetoprotein  Clinical study
FundProject:卫生部科学研究基金资助项目(982048)
Author NameAffiliationE-mail
JIANG Xianmin Beijing Institute of Biological Prodects, Beijing 100024, China  
KONG Jian Beijing Institute of Biological Prodects, Beijing 100024, China kongjian@btamail.net.Cn 
LIN Tao Beijing Institute of Biological Prodects, Beijing 100024, China  
YU Xiuying 青岛大学医学院附属医院  
CHEN Ying 青岛大学医学院附属医院  
DAI Yu 空军总医院  
YANG Hangyan 空军总医院  
SUN Xiaoli 空军总医院  
YANG Jian 中国医学科学肿瘤医院  
YANG Yongquan 中国医学科学肿瘤医院  
ZHANG Yanchun 中国医学科学肿瘤医院  
Hits: 3709
Download times: 1302
Abstract:
      目的用甲胎蛋白放射免疫测定(AFPRIA)试剂盒作对照,测定AFP胶体金诊断试剂的灵敏度及特异度。方法双盲法对426份正常人血清、1567份临床门诊病人血清标本进行检测,以AFPRIA定量测定试剂为判断标准,对卫生部北京生物制品研究所研制的AFP胶体金诊断试剂进行客观的临床考核。结果AFP胶体金诊断试剂在测定正常人血清标本时的假阳性率为1.88%(8426);该试剂在测定临床病人血清标本时的灵敏度达到99.3%(272274)、特异度为97.2%(12571293),与AFPRIA诊断结果的符合率为97.6%。结论AFP胶体金诊断试剂在灵敏度和特异度上均可以和AFPRIA试剂相媲美,可以替代AFPRIA试剂,用于原发性肝癌的筛查
English Abstract:
      Objective To test the sensitivity and specificity of alpha-fetoprotein (AFP) colloidal gold diagnostic strip as compared with RIA-AFP diagnostic kit. Methods Double blind method was used to test sera from 426 healthy people and 1567 patients selected in two general hospitals and a cancer hospital. Each serum was measured by RIA-AFP and AFP colloidal gold diagnostic strip on the same day. RIA-AFP diagnostic results was identified as true positive or negative. Results Among 426 healthy people, all the RIA-AFP test showed negative result (serum AFP concentration less than 25 IU/ml), but the AFP colloidal gold diagnostic strip had 1.88% false positive. When comparing the result from 1 567 patients measured by RIA-AFP, the sensitivity and specificity of AFP colloidal gold diagnostic strip were 99.3%, and 97.2%, respectively. The crude correspondence rate between the two diagnostic regents was 97.6%. Conclusion AFP colloidal gold diagnostic strip showed very good result and could be used as a screening diagnostic kit in clinic and hospital settings.
View Fulltext   Html FullText     View/Add Comment  Download reader
Close