      目的为掌握国产艾滋病病毒(HIV)抗体筛选酶免试剂的实际应用状况,对8种主要的国产HIV抗体筛选酶免试剂进行了临床应用质量评价。方法以一种进口HIV抗体筛选酶免试剂为参比,用8种考评试剂对200份标本进行了统一的检测。200份标本包括100份经过确认的HIV抗体阳性、阴性、可疑标本和100份新疆吸毒人群的血清标本。结果参比试剂可以检出全部74份阳性标本,敏感性为100%,而考评试剂有6~18份不等的假阴性结果,敏感性为81.1%~91.9%。假阴性结果主要发生于来自吸毒人群的HIV抗体弱阳性标本。考评试剂的特异性相对较好,在107份阴性标本中,参比试剂将2份错判为阳性,特异性为98.1%,考评试剂有0~8份标本错判为阳性,特异性为92.5%~100%。结论考评试剂的主要问题是敏感性低,这可能与检测原理是间接法、抗原组成不全面、反应条件不合理等因素有关。